Scigiene's Wireless Gen 2 Temperature Sensor uses an external thermistor probe with a 6' cable to accurately measure temperatures. These sensors are perfect for monitoring ambient temperatures around the sensors physical location. User customization allows you to set the frequency of readings and the ability to set thresholds for alerts via SMS text and/or email. Scigiene's wireless sensors are ideal for pharmaceutical, medical and other high tech applications where loss of data is unacceptable. These also have an amazing range of over 1000 ft. with 10 year battery life and can be remotely upgraded via network connections. These are truly the most advanced wireless sensors available.
Features:
Specifications:
Temperature
Measurement |
Range –
Leaded sensor |
-40°C to
125°C (-40°F to 257°F) |
Range -
Non-leaded sensor: - ALTA
Commercial - ALTA
Enterprise - ALTA
Industrial |
** Limited to
operational range of sensor body 10°C to 50°C (50°F to 122°F) -18°C to 55°C
(-4°F to 122°F) using alkaline batteries -40°C to 85°C
(-40°F to 185°F) | |
Accuracy @
25°C (7°F) |
± 1°C
(±1.8°F) | |
Calibrated
accuracy |
± 0.25°C (±
0.45°F) | |
Resolution |
0.1°C
(0.18°F) | |
Response time |
50 seconds
(10 second time constant)1 | |
Leaded
Probe |
Transducer
Type |
10 KOhm NTC
Thermistor (? = 3455 K) |
Tip dimension |
4.00 mm
(0.157") diameter by 30 mm (1.18") | |
Tip material |
Type 304
stainless steel | |
Cable
material |
Waterproof
high-temperature ABS with EMF shielding | |
Cable
diameter |
3.56 mm
(0.14") | |
Cable length |
Standard:
0.9m (3') Optional:
1.5m (5'), 3m (10'), 7.5m (25'), 50m (50'), 30m (100') | |
Gen 2 Wireless |
Data logging |
Sensor logs
2000 to 4000 readings if gateway connection is lost (non-volatile flash,
persists through power cycling): 10-minute Heartbeats = ~22 days - 2-hour
Heartbeats = ~266 days |
Wireless
protocol |
Gen 2 Proprietary Frequency-Hopping Spread Spectrum (FHSS) | |
Wireless transmission
power (EIRP) |
50 mW
(900MHz), 25 mW (868 MHz), 10 mW (433 MHz) | |
Wireless
range |
2,000+ ft.
through 18+ walls with the Gen 2 XL® Gateway | |
Security |
Encrypt-RF ®
(256-bit key exchange and AES-128 CTR) | |
General |
Battery
voltage range |
2.0 to 3.8
VDC |
Operating
altitude (non-pressurized environments) |
-15.2 to
1,982 m (-50 to 6,500 ft)3 | |
Storage
altitude (non-pressurized environments) |
-15.2 to
3,048 m (-50 to 10,000 ft)3 | |
Operating
humidity |
5 to 85% RH
(non-condensing) | |
Certifications |
900 MHz
sensors: FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. |
|
1. Response time defined as five time constants for
99.3% of actual temperature. 2. Operating and storage altitude without DC power
supply is -30.48 to 9144 m (-100 to 30000 ft). |