The Wireless Gen 2 Low Temperature Sensor uses a PT1000 RTD to accurately measure temperatures from -200°C to +162°C. It is perfect for low temperature critical applications such as freezers and coolers. User customization allows you to set the frequency of sensor readings and create notifications from the system when certain criteria have been met or exceeded. Scigiene's wireless sensors are ideal for pharmaceutical, medical and other high tech applications where loss of data is unacceptable. These also have an amazing range of over 1000 ft. with 10 year battery life and can be remotely upgraded via network connections. These are truly the most advanced wireless sensors available.
Features:
Specifications:
Temperature
Measurement |
Range
- Leaded sensor |
-200°C
to 0°C (-328°F to 32°F) |
Accuracy
@ 0°C (32°F) |
±
3.3°C (±5.9°F) |
|
Calibrated
accuracy @ 0°C (32°F) |
±
0.5°C (± 0.9°F) |
|
Resolution
|
0.1°C
(0.18°F) |
|
Response
time |
50
seconds (10 second time constant) |
|
Leaded
Probe |
Transducer
type |
Glass-coated
platinum RTD (PT1000 RTD), IEC 751-95 Class A, |
Tip
dimension |
4.00
mm (0.157") diameter by 30 mm (1.18") |
|
Tip
material |
Type
304 stainless steel |
|
Cable
material |
Waterproof
Teflon cable with lucency jacket |
|
Cable
diameter |
2.6
mm (0.102") |
|
Cable
length |
Standard:
0.9m (3'), Optional: 3m (10'), 7.5m (25') |
|
General |
Battery
voltage range |
2.0
to 3.8 VDC |
Operating
altitude (non-pressurized environments) |
-15.2
to 1,982 m (-50 to 6,500 ft) |
|
Storage
altitude (non-pressurized environments) |
-15.2
to 3,048 m (-50 to 10,000 ft) |
|
Operating
humidity |
5
to 85% RH (non-condensing) |
|
Certifications
|
900
MHz sensors: FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1 |
|
Battery
|
2x
1.5V AA Alkaline, 1800 mAh, (standard) 2x
1.5V AA Lithium, 3000 mAh, (optional) |
|
Battery
Life |
10+
years expected |
|
External
line-power option |
Input
voltage: 5.0-12.0 V Power
jack: 2.1 x 5.5 mm barrel, center positive |
|
Operating
temperature range (sensor body) |
-18°C
to 55°C (0°F to 130°F) - AA Alkaline Batteries -25°C
to 60°C (-13°F to 140°F) - AA Lithium L91 Batteries 0°C
to 40°C (32°F to 104°F) - US 5V Power Supply 10°C
to 40°C (50°F to 104°F) - International 5V Power Supply |
|
Wireless
antenna type |
1/4-wave,
20-gauge wire whip, 3.5" (900/868MHz), 7"(433MHz) |
|
Weight
|
3.7
oz. (105 g) |
Please call your Scigiene representative for help in designing your wireless system in order to make sure all range and other technical specifications are fully met.
* Actual range may vary depending on environment
** Battery life is determined by sensor reporting frequency and other variables