Scigiene’s Wireless Gen 2 Temperature/Humidity Sensor with probe allows you to monitor the relative humidity of the air within a room or enclosure. It is ideal for monitoring humidity within greenhouses, industrial spaces, museums, saunas and humidors. They can also be used for residential applications such as controlling mold, mildew or dust mites. Scigiene's wireless sensors are ideal for pharmaceutical, medical and other high tech applications where loss of data is unacceptable. These also have an amazing range of over 1000 ft. with 10 year battery life and can be remotely upgraded via network connections. These are truly the most advanced wireless sensors available.
Features:
Specifications:
Humidity
Measurement |
Range |
0 to 100% RH
(non-condensing) |
Accuracy |
± 2% RH (0 to
80%), ± 3% RH (80% to 100%)1 | |
Resolution |
0.01 %RH | |
Response Time
– Leaded sensor |
40 seconds
(8-second time constant)2 | |
Response time
– Non-leaded sensor |
6+ hours
(75-minute time constant)2 | |
Temperature
Measurement |
Range -
Leaded sensor |
-25°C to 70°C
(-13°F to 158°F)3 |
Range -
Non-leaded sensor: - ALTA
Commercial - ALTA
Enterprise - ALTA
Industrial |
** Limited to
operational range of sensor body 10°C to 50°C
(50°F to 122°F) -18°C to 55°C
(0°F to 130°F) using alkaline batteries -40°C to 70°C (-40°F to 158°F) | |
Accuracy |
± 0.3°C
(0.54°F) Typical1 | |
Resolution |
0.01°C
(0.018°F rounded to 0.01 decimal place) | |
Response Time
– Leaded sensor |
15 seconds (3
second time constant)2 | |
Response time
– Non-leaded sensor |
100 minutes
(20 minute time constant)2 | |
Leaded Probe |
Tip dimensions |
11 mm Wide x
4.5 mm Tall (0.44" Wide x 0.16" Tall) |
Tip
construction |
PCA with high
accuracy digital temp/humidity sensing element, soldered interface wires, all
wrapped in waterproof heat shrink with small hole for air exchange. | |
Wire details |
4-conductor,
26 AWG, stranded copper | |
Insulation |
PVC,
0.010" | |
Shield |
No | |
Jacket |
PVC (black) | |
Overall
Diameter |
4.25 ± 0.2 mm
(0.17" ± 0.007) | |
|
Ratings /
Approvals |
UL AWM STYLE
2464, cUL AWM I/II A 80°C 300V FT1 LF |
|
Temperature
Rating |
-25°C to 80°C
(-13°F to 176°F) |
|
Voltage
Rating |
300 V Max |
|
Dielectric
Strength |
1500 V RMS |
|
Cable length |
Standard: 0.9
m (3 ft) Optional:
0.1, 3, 7.5 m (0.33, 10, 25 ft) |
Gen 2 Wireless |
Data logging |
Sensor logs
2000 to 4000 readings if gateway connection is lost (non-volatile flash,
persists through power cycling): 10-minute Heartbeats = ~22 days - 2-hour
Heartbeats = ~266 days |
Wireless
protocol |
Gen 2 Proprietary Frequency-Hopping Spread Spectrum (FHSS) | |
Wireless transmission
power (EIRP) |
50 mW
(900MHz), 25 mW (868 MHz), 10 mW (433 MHz) | |
Wireless
range |
2,000+ ft.
through 18+ walls with the Gen 2 XL® Gateway | |
Security |
Encrypt-RF ®
(256-bit key exchange and AES-128 CTR) | |
General |
Battery
voltage range |
2.0 to 3.8
VDC |
Operating
altitude (non-pressurized environments) |
-15.2 to
1,982 m (-50 to 6,500 ft)4 | |
Storage
altitude (non-pressurized environments) |
-15.2 to
3,048 m (-50 to 10,000 ft)4 | |
Operating
humidity |
5 to 85% RH
(non-condensing) | |
Certifications |
900 MHz
sensors: FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. |
|
1. Refer to the humidity/temperature graphics below
for more detailed information on the sensors accuracy and range. 2. Response time (T of 99.3%) is significantly
affected by air flow and the conditions present in the immediate vicinity of
the sensing element. 3. High temperature limited by heat shrink at 70°C.
The sensor electronics in the lead are rated to 125°C and will not fail at
70°C but the heat shrink and heat shrink adhesive may become malleable at
this temperature compromising the waterproof seal. 4. Operating and storage altitude without DC power
supply is -30.48 to 9144 m (-100 to 30,000 ft). |