Wireless Professional Gen 2 Temperature/Humidity Sensor With External Probe


  • Part #:RFP-0232-P-2
  • Weight:105g
  • Availability: Inquire

Price: $196.35
Price: $265.07


Description

Scigiene’s Wireless Gen 2 Temperature/Humidity Sensor with probe allows you to monitor the relative humidity of the air within a room or enclosure. It is ideal for monitoring humidity within greenhouses, industrial spaces, museums, saunas and humidors. They can also be used for residential applications such as controlling mold, mildew or dust mites.  Scigiene's wireless sensors are ideal for pharmaceutical, medical and other high tech applications where loss of data is unacceptable.  These also have an amazing range of over 1000 ft. with 10 year battery life and can be remotely upgraded via network connections.  These are truly the most advanced wireless sensors available.    

Features:

  • Wireless range of 1,200+ feet through 12+ walls
  • Frequency-Hopping Spread Spectrum (FHSS)
  • Best-in-class interference immunity
  • Best-in-class power management for longer battery life
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Datalogs 2000 to 4000 readings if the gateway connection is lost (non-volatile flash, persists through the power cycle): 10-minute heartbeats = ~ 22 days, 2-hour heartbeats = ~ 266 days
  • Over-the-air updates (future-proof)

Specifications:

Humidity Measurement

Range

0 to 100% RH (non-condensing)

Accuracy

± 2% RH (0 to 80%), ± 3% RH (80% to 100%)1

Resolution

0.01 %RH

Response Time – Leaded sensor

40 seconds (8-second time constant)2

Response time – Non-leaded sensor

6+ hours (75-minute time constant)2

Temperature Measurement

Range - Leaded sensor

-25°C to 70°C (-13°F to 158°F)3

Range - Non-leaded sensor:

- ALTA Commercial

- ALTA Enterprise

- ALTA Industrial

** Limited to operational range of sensor body

10°C to 50°C (50°F to 122°F)

-18°C to 55°C (0°F to 130°F) using alkaline batteries -40°C to 70°C (-40°F to 158°F)

Accuracy

± 0.3°C (0.54°F) Typical1

Resolution

0.01°C (0.018°F rounded to 0.01 decimal place)

Response Time – Leaded sensor

15 seconds (3 second time constant)2

Response time – Non-leaded sensor

100 minutes (20 minute time constant)2

Leaded Probe

Tip dimensions

11 mm Wide x 4.5 mm Tall (0.44" Wide x 0.16" Tall)

Tip construction

PCA with high accuracy digital temp/humidity sensing element, soldered interface wires, all wrapped in waterproof heat shrink with small hole for air exchange.

Wire details

4-conductor, 26 AWG, stranded copper

Insulation

PVC, 0.010"

Shield

No

Jacket

PVC (black)

Overall Diameter

4.25 ± 0.2 mm (0.17" ± 0.007)

 

Ratings / Approvals

UL AWM STYLE 2464, cUL AWM I/II A 80°C 300V FT1 LF

 

Temperature Rating

-25°C to 80°C (-13°F to 176°F)

 

Voltage Rating

300 V Max

 

Dielectric Strength

1500 V RMS

 

Cable length

Standard: 0.9 m (3 ft)

Optional: 0.1, 3, 7.5 m (0.33, 10, 25 ft)

Gen 2  Wireless

Data logging

Sensor logs 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through power cycling): 10-minute Heartbeats = ~22 days - 2-hour Heartbeats = ~266 days

Wireless protocol

Gen 2 Proprietary Frequency-Hopping Spread Spectrum (FHSS)

Wireless transmission power (EIRP)

50 mW (900MHz), 25 mW (868 MHz), 10 mW (433 MHz)

Wireless range

2,000+ ft. through 18+ walls with the Gen 2 XL® Gateway

Security

Encrypt-RF ® (256-bit key exchange and AES-128 CTR)

General

Battery voltage range

2.0 to 3.8 VDC

Operating altitude (non-pressurized environments)

-15.2 to 1,982 m (-50 to 6,500 ft)4

Storage altitude (non-pressurized environments)

-15.2 to 3,048 m (-50 to 10,000 ft)4

Operating humidity

5 to 85% RH (non-condensing)

Certifications

900 MHz sensors: FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1.

1. Refer to the humidity/temperature graphics below for more detailed information on the sensors accuracy and range.

2. Response time (T of 99.3%) is significantly affected by air flow and the conditions present in the immediate vicinity of the sensing element.

3. High temperature limited by heat shrink at 70°C. The sensor electronics in the lead are rated to 125°C and will not fail at 70°C but the heat shrink and heat shrink adhesive may become malleable at this temperature compromising the waterproof seal.

4. Operating and storage altitude without DC power supply is -30.48 to 9144 m (-100 to 30,000 ft).


Required Accessories

Scigiene 21 CFR Part 11 Premiere is a secure cloud based monitoring and notification software dedica (more...)

Part #: RFR-0539-2
$519.75 (USD)
$701.66 (CAD)
The Scigiene GEN 2 4G Industrial Cellular Gateway allows you to control GEN 2 Wireless Sensor settin (more...)

Part #: RFR-0538-2
$404.25 (USD)
$545.74 (CAD)
The Scigiene GEN 2 4G Cellular Gateway allows you to control GEN 2 Wireless Sensor settings without (more...)

Part #: RFR-0526-2
$231.00 (USD)
$311.85 (CAD)
The Gen 2 Ethernet Gateway allows your RF Wireless Sensors to communicate with the Scigiene Premier (more...)

Part #: RFR-0529-2
$288.75 (USD)
$389.81 (CAD)
The GEN2 Modbus Gateway acts as a data concentrator for Scigiene’s GEN 2 long range wireless sensor (more...)