Scigiene’s Wireless Gen 2 Water Detection Sensor alerts you via SMS text and/or email when there is water detected, preventing potential property damage that results from flooding or leaks. Place this sensor anywhere flooding or faulty plumbing could cause a problem. This sensor can also be used to detect a lack of water, allowing you to know when a container is nearing empty. Scigiene's wireless sensors are ideal for pharmaceutical, medical and other high tech applications where loss of data is unacceptable. These also have an amazing range of over 1000 ft. with 10 year battery life and can be remotely upgraded via network connections. These are truly the most advanced wireless sensors available.
Features:
* Actual range may vary depending on environment
** Battery life is determined by sensor reporting frequency and other variables
Specifications:
Detection Requirements |
Input impedance |
2.5 MΩ |
Maximum medium impedance |
900.0 kΩ (Clean water has a typical impedance of 50 to 200 kΩ | |
Detect Lead |
Cable length |
Standard: 0.9 m (3 ft) Optional: 3 m (10'), 7.5 m (25'), 15 m (50'), 30 m
(100') |
Wire count |
2-conductor (red/black) | |
Wire gauge |
22 AWG | |
Conductor material |
Stranded Copper 7/30 | |
Insulation |
PVC, 0.010" | |
Tinning |
Tips Silver(Ag) Solder | |
Shield |
No | |
Jacket |
PVC (black) | |
Overall Diameter |
4.2 mm (0.164") | |
Ratings / Approvals |
NEC (UL) Type CM, UL AWM Style 2464, CSA AWM FT4,
RoHS | |
Temperature Rating |
-20°C to 60°C (-4°F to 140°F) | |
Voltage Rating |
300 V Max2 | |
Dielectric Strength |
1500 V RMS2 | |
Detect+ Probe |
Electrode Composition |
Stainless Steel 304 |
Probe Casing |
ABS Plastic | |
Lead Composition |
Same as the Detect Lead above | |
Gen 2 Wireless |
Data logging |
Sensor logs 2000 to 4000 readings if gateway
connection is lost (non-volatile flash, persists through power cycling):
10-minute Heartbeats = ~22 days - 2-hour Heartbeats = ~266 days |
Wireless protocol |
Gen 2 Proprietary Frequency-Hopping Spread Spectrum
(FHSS) | |
Wireless transmission power (EIRP) |
50 mW (900MHz), 25 mW (868 MHz), 10 mW (433 MHz) | |
Wireless range |
2,000+ ft. through 18+ walls with the Gen 2 XL ®
Gateway | |
Security |
Encrypt-RF ® (256-bit key exchange and AES-128 CTR) | |
General |
Battery voltage range |
2.0 to 3.8 VDC |
Operating altitude (non-pressurized) |
-15.2 to 1,982 m (-50 to 6,500 ft)3 | |
Storage altitude (non-pressurized environments) |
-15.2 to 3,048 m (-50 to 10,000 ft)3 | |
Operating humidity |
5 to 85% RH (non-condensing) | |
Certifications |
900 MHz sensors: FCC ID: ZTL-G2SC1
and IC: 9794A-G2SC1. |
|
1. The resistance between the conductive probe ends
must be less than this to ensure water detection. 2. The input of this sensor is passive. Never apply
any voltage to the water detection lead. 3. Operating and storage altitude without DC power
supply is -30.48 to 9144 m (-100 to 30000 ft). |
Please call your Scigiene representative for help in designing your wireless system in order to make sure all range and other technical specifications are fully met.