Scigiene's Industrial Wireless Gen 2 Temperature sensors use a thermistor probe with a 6" cable to accurately measure temperatures. These sensors are perfect for monitoring ambient temperatures around the sensors physical location. User customization allows you to set the frequency of readings and the ability to set thresholds for alerts via SMS text and/or email.
Features:
Specifications:
Supply voltage |
2.0-3.8 VDC |
|
Current
consumption |
0.2 µA (sleep
mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA
(radio RX mode), 22.6 mA (radio TX mode) |
|
Operating
temperature range (board circuitry and battery) |
-40°C to +85°C
(-40°F to +185°F) |
|
Included battery |
Max temperature
range |
-40° to +85°C
(-40° to +185°F) |
Capacity |
1500 mAh |
|
Optional solar
feature |
Solar panel |
5VDC/30mA (53mm x
30mm) |
Charging
temperature range |
0° to 45°C (32°
to 113°F) |
|
Max temperature
range |
-20° to 60°C (-4°
to 140°F) |
|
Included
rechargeable battery |
600 mAh/>2000
charge cycles (80% of initial capacity) |
|
Solar efficiency |
Optimized for
high and low-light operation |
|
Charging
efficiency |
40% |
|
Luminous
sustainability |
Minimum of 250
LUX |
|
External Probe
and Lead Operating Range |
-40°C to +125°C
(-40°F to +257°F) (Limited to main-unit circuitry, -40°C to +85°C) |
|
Accuracy @ 25°C |
+/- 1% (1° C or
1.8° F) |
|
User-calibrated
accuracy |
+/- 0.25° C (±
0.45° F) |
|
Time constant @
25°C |
30 seconds |
|
Lead |
Probe: 316
stainless steel. Dimensions: 4.8 mm x 25 mm Waterproof Length
Options: 3 ft. (0.91 m) 10 ft. (3.04 m) 25 ft. (7.62 m) 50 ft. (15.24 m) 100 ft. (30.48 m) |
|
Enclosure rating |
NEMA 1, 2, 4, 4x,
12 and 13 rated, sealed and weatherproof |
|
UL rating |
UL Listed to
UL508-4x specifications (File E194432) |
|
Certifications |
900 MHz product;
FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1 |