Wireless Professional Gen 2 Differential Air Pressure Sensor


  • Part #:RFP-0282-2
  • Availability: Inquire

Price: $378.00
Price: $529.20


Description

The Scigiene Wireless Professional Gen 2 Differential Air Pressure Sensor measures the pressure difference between two input ports and transmits the measurement to Scigiene Premiere. When viewing the sensor from the top, the right inlet port is the negative or low side pressure input. When the pressure on this port is greater than the left port the sensor produces a negative pressure reading. When the pressure is greater on the left port the sensor produces a positive pressure reading.

Features:

  • Wireless range of 1,200+ feet through 12+ walls
  • Frequency-Hopping Spread Spectrum (FHSS)
  • Best-in-class interference immunity
  • Best-in-class power management for longer battery life
  • Encrypt-RF ® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Data logs 2000 to 4000 readings if the gateway connection is lost (non-volatile flash, persists through the power cycle): 10-minute heartbeats = ~ 22 days, 2-hour heartbeats = ~ 266 days
  • Over-the-air updates (future-proof) 

Specifications:

Differential Pressure Meter

Lead Tubing

3 ft. (91.5 cm.) 3/16" ID x 5/16" OD x 1/16" Wall Non-DEHP & phtalate-free PVC material

Pressure range

-500 Pa to 500 Pa

Allowable over-pressure

100 kPa

Rated burst pressure

500 kPa

Max humidity for long-term exposure

40°C (104°F) dew point

Accuracy

3% of reading +/- 0.1 Pa

Span repeatability

0.5% of reading

Span shift due to temperature variation

< 0.5% of reading per 10°C (18°F)

Offset stability

< 0.05 Pa/year

Calibrated for

Air, N2

Media compatibility

Air, N2, O2, non-condensing

Temperature measurement range

-40°C to 85°C (-40°F to 185°F)

Calibrated temperature measurement range

-20°C to 85°C (-4°F to 185°F)

Temperature resolution

0.1°C (0.18°F)

Temperature accuracy

+/- 2°C (-10°C to 60°C), +/- 3°C (-40°C to 85°C) +/- 3.6°F (14°F to 140°F), +/- 5.4°F (-40°F to 185°F)

Temperature repeatability

+/- 0.1°C (+/- 0.18°F)

Gen 2 Wireless

Data logging

Sensor logs 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through power cycling): 10-minute Heartbeats = ~22 days - 2-hour Heartbeats = ~266 days

Wireless protocol

Gen 2 Proprietary Frequency-Hopping Spread Spectrum (FHSS)

Wireless transmission power (EIRP)

50 mW (900MHz), 25 mW (868 MHz), 10 mW (433 MHz)

Wireless range

2,000+ ft. through 18+ walls with the Gen 2 XL ® Gateway

Security

Encrypt-RF ® (256-bit key exchange and AES-128 CTR)

General

Battery voltage range

2.0 to 3.8 VDC

Operating altitude (non-pressurized)

-15.2 to 1,982 m (-50 to 6,500 ft)3

Storage altitude (non-pressurized environments)

-15.2 to 3,048 m (-50 to 10,000 ft)3

Operating humidity

5 to 85% RH (non-condensing)

Certifications

900 MHz sensors: FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1.

1. Operating and storage altitude without DC power supply is -30.48 to 9144 m (-100 to 30000 ft)


Please call your Scigiene representative for help in designing your wireless system in order to make sure all range and other technical specifications are fully met.

Technical Information

Required Accessories

Scigiene 21 CFR Part 11 Premiere is a secure cloud based monitoring and notification software dedica (more...)

Part #: RFR-0539-2
$519.75 (USD)
$727.65 (CAD)
The Scigiene GEN 2 4G Industrial Cellular Gateway allows you to control GEN 2 Wireless Sensor settin (more...)

Part #: RFR-0538-2
$404.25 (USD)
$565.95 (CAD)
The Scigiene GEN 2 4G Cellular Gateway allows you to control GEN 2 Wireless Sensor settings without (more...)

Part #: RFR-0526-2
$231.00 (USD)
$323.40 (CAD)
The Gen 2 Ethernet Gateway allows your RF Wireless Sensors to communicate with the Scigiene Premier (more...)

Part #: RFR-0529-2
$288.75 (USD)
$404.25 (CAD)
The GEN2 Modbus Gateway acts as a data concentrator for Scigiene’s GEN 2 long range wireless sensor (more...)