Scigiene’s GEN 2 Wireless G-Force Max/Avg Sensor
reports the maximum and average g-force levels that occur on X, Y, Z, and
combined axes in-between sensor heartbeats. The sensor uses a digital, low
power, low profile, capacitive accelerometer capable of measuring acceleration
on three axes to produce this data.
Features:
Specifications:
Supply voltage |
2.0-3.8 VDC
(3.0-3.8 VDC using power supply) |
|||||||
Current
consumption |
0.2 µA (sleep
mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA
(radio RX mode), 22.6 mA (radio TX mode) |
|||||||
Operating
temperature range (board circuitry and battery) |
-40°C to +85°C
(-40°F to +185°F)* |
|||||||
Included battery |
Max temperature
range |
-40° to +85°C
(-40° to +185°F) |
||||||
Capacity |
1500 mAh |
|||||||
Optional solar
feature |
Solar panel |
5VDC/30mA (53mm x
30mm)VDC/30mA (53mm x 30mm) |
||||||
Charging
temperature range |
0° to 45°C (32°
to 113°F) |
|||||||
Max temperature
range |
20° to 60°C (-4°
to 140°F) |
|||||||
Included
rechargeable battery |
3.2 V LiFePO4 AA
sized |
|||||||
600 mAh/>2000
charge cycles (80% of initial capacity) |
||||||||
If the battery is
kept at ~80% charge it can last up to 20 years. |
||||||||
Solar efficiency |
Optimized for
high and low-light operation |
|||||||
Charging
efficiency |
40% |
|||||||
Luminous
sustainability |
Minimum of 250
LUX (Works indoors with low light) |
|||||||
Integrated memory |
Up to 3200 sensor
messages |
|||||||
Weight |
4.7 ounces |
|||||||
Enclosure rating |
NEMA 1, 2, 4, 4x,
12 and 13 rated, sealed and weather proof |
|||||||
UL rating |
UL Listed to
UL508-4x specifications (File E194432) |
|||||||
Certifications |
900 MHz product;
FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. |
|||||||
Solar Charge
Current for Different LUX Levels (Assuming light at given LUX level is
present for 25% of the day)* |
||||||||
Environment |
LUX Level |
Charge / Hour
(mAh) |
Charge / Day
(mAh) |
Charge / Year
(mAh) |
||||
Low Office
Lighting |
250 |
0.039063 |
0.234375 |
85.5469 |
||||
Avg Office
Lighting |
500 |
0.078125 |
0.46875 |
171.094 |
||||
High Office
Lighting |
750 |
0.117188 |
0.703125 |
256.641 |
||||
Overcast Day |
1000 |
0.15625 |
0.9375 |
342.188 |
||||
Full Daylight |
10000 |
1.5625 |
9.375 |
3421.88 |
||||
Sensor
Specifications |
||||||||
Current
consumption |
6 Hz - 32.4 uA: ~
4 year lifetime at 10+ minute heartbeat.* 12 Hz - 36.2 uA:
~ 4 year lifetime at 10+ minute heartbeat. 50 Hz - 66.5 uA:
~ 2 year lifetime at 10+ minute heartbeat. 100
Hz - 125.6 uA: ~ 1 year lifetime at 10+ minute heartbeat. |
|||||||
Accelerometer
Current Consumption (Based on Output Data Rate) |
6 Hz |
12 Hz |
50 Hz |
100 Hz |
||||
|
32.4 uA |
36.2 uA |
66.5 uA |
125.6 uA |
||||
Range (XYZ) |
2 G, 4 G, 8 G
(User Configurable) |
|||||||
Sensitivity |
4096 count/g @ 2
G, 2048 count/g @ 4 G, 1024 count/g @ 8 G |
|||||||
Measurement
accuracy |
2.5 % (force: X,
Y, Z) |
|||||||
Output Data Rate |
6 Hz, 12 Hz, 50
Hz, 100 Hz (User Configurable) |
|||||||
High Pass Filter |
Filters out frequencies
below ~4 Hz when activated (User Configurable) |
|||||||
Resolution |
0.001 g |