Scigiene's Industrial Wireless Gen 2 open/closed sensors provide information on the status of doors, windows, cabinets, etc. The sensor can let you know if a building or area is being accessed when it should not be, or if a door or window has been left open. Alerts can be setup to notify a user by SMS text, email or voice call if a door or window has been opened or left open.
Features:
Specifications:
Supply voltage |
2.0–3.8 VDC |
|
Current consumption |
0.2 µA (sleep mode), 0.7 µA (RTC sleep), 570
µA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX
mode) |
|
Operating temperature range (board circuitry
and battery) |
-40°C to +85°C (-40°F to +185°F) |
|
Included battery |
Max temperature range |
-40° to +85°C (-40° to +185°F) |
Capacity |
1500 mAh |
|
Optional solar feature |
Solar panel |
5VDC/30mA (53mm x 30mm) |
Charging temperature range |
0° to 45°C (32° to 113°F) |
|
Max temperature range |
-20° to 60°C (-4° to 140°F) |
|
Included rechargeable battery |
600 mAh/>2000 charge cycles (80% of initial
capacity) |
|
Solar efficiency |
Optimized for high and low-light operation *** |
|
Charging efficiency |
40% |
|
Luminous sustainability |
Minimum of 250 LUX |
|
Magnetic Switch |
SPST, gold under -plating with Deactivated
Rhodium outer-plating (capable of 50 million activations) |
|
Operation Gap |
Up to 3/4 inch |
|
Wire Leads |
22 gauge/15 inch length |
|
Magnet |
Alnico magnet/Weatherproof, high-impact ABS
plastic covering with self-adhesive backing |
|
Magnet temperature range |
-15°F to 160°F (-25°C to 70°C) |
|
Enclosure rating |
NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and
weatherproof |
|
UL rating |
UL Listed to UL508-4x specifications (File
E194432) |
|
Certifications |
900 MHz product; FCC ID: ZTL-G2SC1 and IC: