Scigiene's Industrial Wireless Gen 2 voltage meters are capable of measuring the voltage off another device, battery, or sensor. This sensor is capable of measuring voltage up to 5 VDC (See related products for more voltage options) by connecting the leads on the sensor to the positive and ground terminals of the device being measured.
Features:
* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting
frequency and other variables. Other power options
are also available.
Specifications:
Supply voltage |
2.0–3.8 VDC
(3.0–3.8 VDC using power supply) * |
|
Current
consumption |
0.2 µA (sleep
mode), 0.7 µA (RTC sleep), 570 µA (MCU idle), 2.5 mA (MCU active), 5.5 mA
(radio RX mode), 22.6 mA (radio TX mode) |
|
Operating
temperature range (board circuitry and battery) |
-40°C to +85°C
(-40°F to +185°F) |
|
Included battery |
Max temperature
range |
-40° to +85°C
(-40° to +185°F) |
Capacity |
1500 mAh |
|
Optional solar
feature |
Solar panel |
5VDC/30mA (53mm x
30mm) |
Charging
temperature range |
0° to 45°C (32°
to 113°F) |
|
Max temperature
range |
-20° to 60°C (-4°
to 140°F) |
|
Included
rechargeable battery |
600 mAh/>2000
charge cycles (80% of initial capacity) |
|
Solar efficiency |
Optimized for
high and low-light operation ** |
|
Charging
efficiency |
40% ***** |
|
Luminous
sustainability |
Minimum of 250
LUX ***** |
|
Voltage range |
0–5 Volts DC*** |
|
Resolution |
~1 mV |
|
Accuracy |
+/- (0.006 VDC +
3.0% of Reading) |
|
User-calibrated
accuracy |
+/- (0.003 VDC +
0.5% of Reading) *** |
|
Open circuit
voltage |
~0.00 Volts |
|
Max rated input |
10 Volts |
|
Input Impedance |
13 kOhms |
|
Lead wire length |
2 Wires, 1 ft (12
in), Red (+), Black (-), 18 AWG (Custom lengths available upon request) |
|
Enclosure rating |
NEMA 1, 2, 4, 4x,
12 and 13 rated, sealed and weatherproof |
|
UL rating |
UL Listed to
UL508-4x specifications (File E194432) |
|
Certifications |
900 MHz product;
FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1 |
** Light present 25% of day yields 125% of operating power to support 10-minute heartbeats.
*** The sensor is capable of measuring above 5 volts but may not meet the specified accuracy above this value.
**** For best results calibrate at a voltage between 50% and 90% of the voltage range. Industry Canada
***** Solar feature’s energy harvesting circuitry works indoors with low light.