Scigiene's Wireless Gen 2, 0-20 mA Current Meter is capable of measuring the current off another device or sensor, up to 20 mA (DC), by connecting the leads of the sensor to the positive and ground terminals of the device being measured. Examples of interfacing devices include, but are not limited to: Current transducers (CTs) with outputs up to 20 mA, pH sensor, dissolved oxygen sensor, pressure sensor, magnetic flow meters, velocity or acceleration sensors, industrial vibration sensors, industrial accelerometers, any kind of sensor that specifies the output is in (mA) within the range of 0 – 20. Scigiene's wireless sensors are ideal for pharmaceutical, medical and other high tech applications where loss of data is unacceptable. These also have an amazing range of over 1000 ft. with 10 year battery life and can be remotely upgraded via network connections. These are truly the most advanced wireless sensors available.
Features:
Specifications:
Current
Meter |
Measurement Range |
0-20 mA1 |
Sensor
resolution |
~ 0.01 mA
(11-bit single ended) | |
Accuracy |
Uncalibrated:
0.35mA (typical), 0.7mA (worst case) Calibrated: 0.05mA | |
Conversion
time |
228 us | |
Load
resistance |
51 ohms | |
Load Voltage
(@ 20mA) |
1.02 V | |
Lead |
Cable length |
Standard: 0.3
m (1 ft) |
Wire count |
2-conductor
(red/black) | |
Wire gauge |
22 AWG | |
Conductor
material |
Stranded
Copper 7/30 | |
Insultation |
PVC,
0.010" | |
Shield |
No | |
Jacket |
PVC (black) | |
Overall
Diameter |
4.2 mm
(0.164") | |
Ratings /
Approvals |
NEC (UL) Type
CM, UL AWM Style 2464, CSA AWM FT4, RoHS/Reach Compliant | |
Temperature Rating |
-20°C to 85°C
(-4°F to 185°F)2 | |
Voltage
Rating |
300 V Max | |
Dielectric
Strength |
1500 V RMS | |
Gen 2 Wireless |
Data logging |
Sensor logs
2000 to 4000 readings if gateway connection is lost (non-volatile flash,
persists through power cycling): 10-minute Heartbeats = ~22 days - 2-hour
Heartbeats = ~266 days |
Wireless
protocol |
Gen 2 Proprietary Frequency-Hopping Spread Spectrum (FHSS) | |
Wireless transmission
power (EIRP) |
50 mW
(900MHz), 25 mW (868 MHz), 10 mW (433 MHz) | |
Wireless
range |
2,000+ ft.
through 18+ walls with the Gen 2 XL® Gateway | |
Security |
Encrypt-RF ®
(256-bit key exchange and AES-128 CTR) | |
General |
Battery
voltage range |
2.0 to 3.8
VDC |
Operating
altitude (non-pressurized environments) |
-15.2 to
1,982 m (-50 to 6,500 ft)3 | |
Storage
altitude (non-pressurized environments) |
-15.2 to
3,048 m (-50 to 10,000 ft)3 | |
Operating
humidity |
5 to 85% RH
(non-condensing) | |
Certifications |
900 MHz
sensors: FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. |
|
1. If application exceeds 20 mA the sensor will
return a maximum reading of 20 mA. If current applied to measurement port exceeds
30 mA, circuit protection and conditioning is required. 2. Temperatures colder than the rating are acceptable
if the cable is not moving or vibrating. 3. Operating and storage altitude without DC power
supply is -30.48 to 9144 m (-100 to 30000 ft). |
* Actual range may vary depending on environment
** Battery life is determined by sensor reporting frequency and other variables