Imminent danger of CO poisoning is a growing concern in the care for elderly, child and immuno-compromised individuals. Scigiene's Wireless Professional Gen 2 Carbon Monoxide (CO) Gas Sensor platform and online monitoring software provide a very affordable, simple-to-setup, feature rich solution that helps meet the growing demand of legislative and public concerns regarding the monitoring of gas leaks and emissions. The mems based wireless carbon monoxide sensor allows you to monitor the level of carbon monoxide (CO) gas in the surrounding air. The Wireless Professional Gen 2 Carbon Monoxide (CO) Gas Sensors have a small footprint and low cost but boast industry leading, premium performance specifications and are the longest lifetime sensors in the industry and the only CO sensor on the market powered by a coin cell battery (battery lasts over a year at 1 hour heartbeat). User customization allows you to set the frequency of readings and the ability to set customized alerts via SMS text or email when the sensor detects CO levels outside of the user's defined safe levels.
Features:
* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency
and other variables. Other power options are also available.
Specifications:
Supply voltage |
2.0 - 3.6 VDC
(3.0 - 3.6 VDC Using Power Supply) |
Current
Consumption |
0.7 µA (sleep
mode), 2 mA (radio idle/off mode), 2 mA (measurement mode), 25 mA (radio RX
mode), 35 mA (radio TX mode) |
Operating
Temperature Range (Board Circuitry and Batteries) |
-30°C to 55°C
(-20°F to 130°F) using alkaline -40°C to 85°C
(-40°F to 185°F) using lithium |
Optimal Battery
Temperature Range (AA) |
+10°C to +50°C (
+50°F to +122°F ) |
Operating
Pressure Range |
± 0.2 atm
(recommended) |
Operating
Humidity Range |
15 to 95% RH |
Measuring Range |
0-1000 PPM |
Maximum Overload |
1000 PPM |
Measuring
Principle |
Electrochemical
Oxidation of CO |
Resolution |
± 1 PPM |
Response Time
(t-90) |
< 40 seconds
typical at 20°C |
Stabilization
Time |
< 120 seconds |
Long Term Drift -
Zero |
Zero Signal <
± 2 PPM / month |
Long Term Drift -
Span |
Output Signal <
± 2% of reading per month |
Maximum Zero
Shift |
< 8 ppm
equivalent (-20°C to +40°C) |
Certifications |
900 MHz product;
FCC ID: ZTL- G2SC1 and IC: 9794A-RFSC1. 920 MHz product; ARIB STD-T108
R210-103733 |
** Accuracy is based at typical operating temperature and pressure (25 degrees C and 1 Atmosphere (sea level))
Please call your Scigiene representative for help in designing your wireless system in order to make sure all range and other technical specifications are fully met.