CleanTrust ATP Surface MagniSwab


  • Part #:ATP0012
  • Units:100/cs
  • Availability: Inquire

Price: $416.69
Price: $604.20


Description

The CleanTrust MagniSwab is the most sensitive and chemical resistant ATP test swab available on the market. Designed to work with the ATP3500 and ATP3900 Luminometers.

The MagniSwab detects extremely low levels of ATP (Adenosine Triphosphate) to 1*10-18 mol and resistant  residual sanitizer and chemicals to over 1000 ppm.

1. For high sensitivity hygiene monitoring - the MagniSwab is at least 500x more sensitive than other ATP swabs

2. For hygiene monitoring "Post Sanitation": MagniSwab is the only ATP Swab with this degree of buffering making it ideal for use in critical environments like hospitals and clinical settings

Features & Benefits:

  • Simple, user-friendly all-in-one device
  • Uses Snap Valve technology for simple 3-step utilization: Swab, Snap and Read.
  • Resistant to over 1000 ppm of sanitizers where competitive products are completely deactivated.
  • Improved Sensitivity – over 500x more sensitive than other ATP swabs
  • Increased buffering capacity in difficult situations with increased salts, sanitizers or other chemical residues.
  • Consistent, reliable, reproducible results 15 seconds!
  • The increased sensitivity at the low end makes it better for cross-correlation between low allergens and low RLU’s.
  • Self-contained, liquid-stable reagent eliminates all reagent preparation and extraction
  • Premoistened swab bud and write-on swab label
  • Tolerant to temperature abuse
  • 100 tests per case
  • Allow the ATP Surface MagniSwab to equilibrate to room temperature (20-25) before use.
  • The swab tip is pre-moistened for maximum sample collection.
  • Condensation may be visible on the inside of the swab tube; this is normal.


Interpretation of Results

The ATP Surface MagniSwab can be used with the ATP3500 or ATP3900 luminometer. These luminometers are pre-set with pass and fail RLU thresholds, and the results can be interpreted according to Table 1. Users are recommended to set the thresholds in accordance with the standards of their respective institutions or industries.


  Table 1. Default RLU Threshold Settings of the Luminometer

Luminometer

Threshold

Result

 

ATP3500

0-20

Pass (Clean)

20-60

Caution (Warning)

>60

Fail (Dirty)

 

ATP3900

0-1000

Pass (Clean)

1000-3000

Caution (Warning)

>3000

Fail (Dirty)


Storage and Shelf Life

12 months at refrigerated temperatures (2°C to 8ºC) or 4 weeks room temperature (21°C to 25ºC)

Optional Accessories

Part #: ATP3500
$1,551.72 (USD)
$2,250.00 (CAD)
The CleanTrust Touch Hygiene Luminometer benchmarks the most advanced and sensitive Luminometer, an (more...)

The CleanTrust Touch Hygiene Luminometer benchmarks the most advanced and sensitive Luminometer, an (more...)

Part #: ATP3900
$3,360.00 (USD)
$4,872.00 (CAD)
The CleanTrust Touch V2 Hygiene Luminometer benchmarks the most advanced and sensitive Luminometer, (more...)

The CleanTrust Touch V2 Hygiene Luminometer benchmarks the most advanced and sensitive Luminometer, (more...)